Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Physiol Rep ; 11(4): e15602, 2023 02.
Article in English | MEDLINE | ID: covidwho-2282398

ABSTRACT

Optimal oxygenation in the intensive care unit requires adequate pulmonary gas exchange, oxygen-carrying capacity in the form of hemoglobin, sufficient delivery of oxygenated hemoglobin to the tissue, and an appropriate tissue oxygen demand. In this Case Study in Physiology, we describe a patient with COVID-19 whose pulmonary gas exchange and oxygen delivery were severely compromised by COVID-19 pneumonia requiring extracorporeal membrane oxygenation (ECMO) support. His clinical course was complicated by a secondary superinfection with staphylococcus aureus and sepsis. This case study is provided with two goals in mind (1) We outline how basic physiology was used to address life-threatening consequences of a novel infection-COVID-19. (2) We describe a strategy of whole-body cooling to lower the cardiac output and oxygen consumption, use of the shunt equation to optimize flow to the ECMO circuit, and transfusion to improve oxygen-carrying capacity when ECMO alone failed to provide sufficient oxygenation.


Subject(s)
COVID-19 , Superinfection , Humans , Superinfection/therapy , Cardiac Output , Oxygen , Hemoglobins
2.
JTCVS Tech ; 14: 55-65, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-1882629

ABSTRACT

Objectives: Geometric ring annuloplasty has shown promise during bicuspid aortic valve repair for aortic insufficiency. This study examined early outcomes of bicuspid aortic valve repair associated with proximal aortic aneurysm replacement. Methods: From September 2017 to November, 2021, 127 patients underwent bicuspid aortic valve repair with concomitant proximal aneurysm reconstruction. Patient age was 50.6 ± 12.7 years (mean ± standard deviation), male gender was 83%, New York Heart Association Class was 2 (1-2) (median [interquartile range]), and preoperative aortic insufficiency grade was 3 (2-4). Ascending aortic diameter was 50 (46-54) mm, and all patients had ascending aortic replacement. Forty patients had sinus diameters greater than 45 mm, prompting remodeling root procedures. A total of 105 patients had Sievers type 1 valves, 3 patients had type 0, and 7 patients had type 2. A total of 118 patients had primarily right/left fusion, 8 patients had right/nonfusion, and 1 patient had left/nonfusion. Leaflet reconstruction used central leaflet plication and cleft closure, with limited ultrasonic decalcification in 31 patients. Results: Ring size was 23 (21-23) mm, and 26 of 40 root procedures were selective nonfused sinus replacements. Aortic clamp time was 139 (112-170) minutes, and bypass time was 178 (138-217) minutes. Postrepair aortic insufficiency grade was 0 (0-0) (P < .0001), and mean valve gradient was 10 (7-14) mm Hg. No early and 1 late mortality occurred. Four patients required reoperation for bleeding, and 4 patients required pacemakers. At a mean follow-up of 20 months (maximal 93), there were no valve-related complications, 5 late repair failures prompting valve replacement, and 1 death due to Coronavirus Disease 2019. Conclusions: Geometric ring annuloplasty for bicuspid aortic valve repair with proximal aortic aneurysm reconstruction is safe and associated with good early outcomes. Further experience and follow-up will help inform long-term durability.

SELECTION OF CITATIONS
SEARCH DETAIL